Desktop NIR Composition Meter — Moisture, Water Activity, Fat, Protein, and More in Seconds
Measure multiple organic components simultaneously with a single non-destructive test. Test results are instant. Even when averaging across a varied sample, the final reading is returned in under 10 seconds. The KB270 uses near-infrared light to deliver lab-grade composition data without chemicals, sample destruction, or specialized training.
Multi-Component Analysis: Measure moisture, water activity, fat, protein, solids, BTU, coat weight, film thickness, and calculated ash from one instrument.
50 Stored Calibrations: Switch between products and parameters instantly. Password protection prevents unauthorized changes.
Non-Destructive: NIR light does not alter the sample. Test and return it to the batch or use it for additional analysis.
Online NIR Composition Meter — Production-Grade Multi-Component Analysis on Open Process Lines
Measure moisture, water activity, protein, fat, oil, sugar, solvent, alcohol, coat weight and film thickness simultaneously — continuously, on a moving production line, without contact or sample preparation. The KJT700 is the production-grade online NIR analyzer Kett has refined across thousands of installations: belt conveyors, screw conveyors, sluices and any process where the product is visible to the sensor.
Multi-Component Simultaneous Analysis: Measure up to 9 organic components in a single reading — moisture plus protein, fat, oil, sugar, solvent, alcohol, coat weight and film thickness, depending on configuration.
0.1 Second Refresh: Real-time process monitoring at the speed of the line. Out-of-spec excursions trigger automated adjustments before product is wasted.
Production-Grade Construction: NEMA 12 housing, integrated air purge snout, optional explosion-proof and CIP configurations. Built for the harshest process environments.
99 Calibrations Per Head: Switch between products, recipes or grades on the same line without rebuilding calibrations. Up to 32 sensor heads on a single PC connection for multi-point installations.
Inline Fiber Optic NIR Composition Meter — See Inside Enclosed Processes
Measure moisture, protein, fat, oil and other organic components simultaneously inside processes you cannot see into — mixers, blenders, pneumatic and vacuum conveyors, extruders, spray and fluid bed dryers. The KJT270F's fiber optic probe separates the measurement point from the electronics, reaching into enclosed, hot, hazardous or restricted spaces where standard sensors won't fit.
Fiber Optic Probe Architecture: The optical probe mounts at the measurement point; the controller mounts where you have space, power and access. Reach inside vessels, around obstructions, into hazardous zones — without compromising sensor placement.
Enclosed and Hazardous Process Capable: CIP-compatible and explosion-proof configurations are available. Mount the probe inside mixers, dryers and conveying systems where the product is invisible from outside.
Full Multi-Component Composition: Simultaneous moisture, water activity, protein, fat, oil, sugar, solvent, alcohol, coat weight and film thickness — same measurement capability as the production-grade KJT700, in a fiber optic form factor.
Small-Sample and Specialty Applications: The 26 mm measurement spot suits narrow online targets — wet streaks, adhesive strips, print strips, coated webs — where a larger sensor footprint won't work.
Online NIR Composition Analyzer — Resolves Totals Into Individual Constituents, in Real Time, on the Line
The BSR1700 reads the full near-infrared spectrum as product passes beneath it, so it does more than report a total. It resolves that total into the individual constituents that make it up: not just total fat, but the individual fatty acids; not just total sugar, but the separate sugars. Continuous composition data on your process line, without contact and without waiting for the lab.
Sees individual constituents, not just totals: Full-spectrum measurement separates a combined value into its parts, where a filter-based sensor returns one aggregate number.
Up to three components at once: Measure up to three organic components simultaneously across the 900 to 1700 nm NIR band.
Non-contact, real-time: Reads from a 50 to 100 mm standoff with no sample contact, so production never stops for a measurement.
Runs standalone: Store up to 100 calibration channels on the instrument and run disconnected from the PC once your calibrations are loaded.
Online NIR Composition Analyzer for High-Moisture Product — Resolves Totals Into Individual Constituents, in Real Time, on the Line
The BSR1000 reads the full near-infrared spectrum as product passes beneath it, so it does more than report a total. It resolves that total into the individual constituents that make it up: not just total fat, but the individual fatty acids; not just total sugar, but the separate sugars. Its 640 to 1050 nm band is suited to high-moisture product, delivering continuous composition data on your process line without contact and without waiting for the lab.
Sees individual constituents, not just totals: Full-spectrum measurement separates a combined value into its parts, where a filter-based sensor returns one aggregate number.
Tuned for high-moisture product: The 640 to 1050 nm band measures composition in samples with high water content across this range.
Non-contact, real-time: Reads from a 50 to 100 mm standoff with no sample contact, so production never stops for a measurement.
Runs standalone: Store up to 100 calibration channels on the instrument and run disconnected from the PC once your calibrations are loaded.
Inline NIR Composition Analyzer — Resolves Totals Into Individual Constituents, in Real Time, Inside Your Process
The BSF1700 measures composition where you cannot see it: inside dryers, convey lines, and liquid streams. Reading the full near-infrared spectrum through fiber-optic probes, it does more than report a total. It resolves that total into the individual constituents that make it up: not just total fat, but the individual fatty acids; not just total sugar, but the separate sugars. Continuous composition data from inside your process, without sampling and without waiting for the lab.
Sees individual constituents, not just totals: Full-spectrum measurement separates a combined value into its parts, where a filter-based sensor returns one aggregate number.
Measures inside the process: Fiber-optic probes reach into spray dryers, fluid bed dryers, pneumatic and vacuum convey lines, and liquid applications, in both reflection and transmission.
Up to three components at once: Measure up to three organic components simultaneously across the 900 to 1700 nm NIR band.
Runs standalone: Store up to 100 calibration channels on the instrument and run disconnected from the PC once your calibrations are loaded.