Welcome to Kett - Tomorrow's Testing Today

USD|ENG

LE900 Integrated Ferrous Coating Thickness Gauge

Integrated Ferrous Coating Gauge — no Longer in production

The LE900 measured non-magnetic coatings on iron and steel from a single integrated probe body. It has been replaced by the LZ990, which reads both ferrous and non-ferrous substrates automatically in one one-piece tool.

  • Ferrous measurement: electromagnetic readings on iron and steel, iron substrate included
  • Integrated probe: sealed handheld body, spring-loaded probe for curved and edged parts
  • Replaced by the LZ990: adds non-ferrous, longer range, memory, and PC output in the same form factor

$785.00

Description

The LE900 Ferrous Coating Gauge: Now Consolidated Into the LZ990

The LE900 measured non-magnetic coatings (paint, plating, anodizing) on iron and steel using a single integrated probe. It is no longer manufactured. Its measurement role is now part of the LZ990, a one-piece gauge that reads ferrous and non-ferrous substrates automatically, so a shop no longer needs a separate tool for each metal type.

What the LE900 Did

  • Ferrous-only measurement: electromagnetic measurement of non-magnetic coatings on iron and steel, with the iron (FE-J) calibration substrate included.
  • Integrated probe body: a single sealed handheld with a spring-loaded probe for curved and edged parts, no separate cable to manage.
  • Field-ready range and accuracy: 0 to 1500 um (0 to 60 mils), accuracy of plus or minus 1 um below 50 um and plus or minus 2% above, on roughly 40 hours of battery life.

Why the LZ990 Replaces It

Your LE900 measured coatings on steel only. The LZ990 adds non-ferrous measurement in the same one-piece tool, detecting the substrate automatically with no mode to set. It also extends the range to 2000 um, adds onboard memory for roughly 1000 readings with statistics and lot functions, moves to 16 calibration channels, and adds USB and RS-232C output, none of which the LE900 had. Accuracy is unchanged: the LE900 already met the same specification.

Looking for a current replacement? The LZ990 Integrated Coating Thickness Gauge reads ferrous and non-ferrous substrates automatically in one sealed body.

Additional information

Weight 1.6 lbs
Dimensions 9 × 6 × 2 in
Measurement Principle

Electromagnetic

Measurement Range

0 to 1500 µm (0 to 60.0 mils)

Accuracy

±1 µm under 50 µm; ±2% at 50 µm and greater

Resolution

0.1 µm under 100 µm; 1 µm at 100 µm and above

Response Time

Instant

Applications

Non-magnetic coatings on magnetic metal

Calibrations

Range-based 2-point calibration

Substrate Compatibility

Iron and steel

Display

Digital LCD, minimum displayed digit 0.1 µm

Features

Lower-limit alarm, unit selection (µm/mils), value hold, auto power off (15 min)

Operating Temperature

0 to 40 °C

Operating Humidity

0 to 85% RH, non-condensing

Power

2 x AAA alkaline (1.5 V), included

Battery Life

Approximately 40 hours (continuous use)

Dimensions

80 (W) × 80 (D) × 31 (H) mm

Weight

0.1 kg (0.22 lbs)

Standard Accessories

Iron substrate (FEJ), plastic calibration foils (50/100/800 µm), foil case, 2 x AAA batteries, carrying pouch, operating manual

Options

Beryllium copper calibration foil

Warranty

One Year Total Care Warranty covering parts, labor, and specification compliance. Maintenance Agreements available.

Reviews

There are no reviews yet.

Be the first to review “LE900 Integrated Ferrous Coating Thickness Gauge”

Your email address will not be published. Required fields are marked *

The questions is empty.