Description
The Inclined Paddle in the Blade System
Angled paddles that push material axially while sweeping it around: the chart’s circulation choice as viscosity climbs past what a propeller can move. Heidon’s selection chart places it in the circulation column for syrups and shampoos around 10,000 mPa·s, and honey-thick batches to 50,000 mPa·s when stacked. Available in ø40, ø80, ø100, ø120 mm.
Choosing It Over the Alternatives
- Multi-stage stacking: two or three paddles on one shaft carry circulation into the 50,000 mPa·s range
- Vessel match: above 10,000 mPa·s, choose a blade diameter of at least 60 percent of the vessel diameter; the size steps in this line exist for that rule
- Combination mixing: pair a shear blade with a circulation blade on one shaft when a batch needs both dispersing and turnover
In the Box and On the Shaft
Blade only; shafts are sold separately and in the FS blade sets. Fits every Three-One Motor mixer that takes the ø8 mm shaft. Backed by our One-Year Total Care Warranty covering parts, labor, and specification compliance.
Need the shaft too? The ø8 mm Mixing Shaft SUS-316 comes in five lengths with the retaining nut included.